  • Cervi S.A. | LSHF shielded intercom cable
    shield Longitudinal overlapping aluminium polyester tape A 0 4 mm Ø tin plated copper drain wire will be applied in contact with the aluminium 6 Outer cover Outer cover TM 51 type PVC according to UNE EN 50290 2 22 Grey cover Test voltage CC 1000 V Temperature range 15 ºC to 70 ºC Radius of curvature 5 times the outer diameter of the cable mm Electrical data Capacitance imbalances pF km 800 Hz pair pair Max average value 45 Maximum value 260 Resistance imbalance 2 5 Max Mutual capacity nF km 1000 Hz Max average value 45 Maximum value 260 Nominal attenuation Cond diameter mm 0 50 0 8 kHz dB km 1 30 1000 kHz dB km 21 4 Used in indoor telephone installations small private installations and switching systems and equipment connection Shielded version for where interference may be caused by other equipment Suitable for installations in public spaces Flame retardant UNE EN 60332 1 Halogen free UNE EN 50267 2 1 IEC 60754 1 Low smoke opacity UNE EN 50268 IEC 61034 Low corrosiveness gases UNE EN 50267 2 2 IEC 60754 2 Colour code Pair no 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Pilot Conductor 1 White White White White White Red Red Red Red Red Black Black Black Black Black Yellow Yellow Yellow Yellow Yellow Violet Violet Violet Violet Violet White Conductor 1 Blue Orange Green Brown Gray Blue Orange Green Brown Gray Blue Orange Green Brown Gray Blue Orange Green Brown Gray Blue Orange Green Brown Gray Black Bindings Unit 1 2 3 4 5 Binding colour U 25 White White White White White Construction data LSHF shielded intercom cable Code 32164602 32164902 32165002 32165102

    Original URL path: http://www.cervi.es/english/products/ficha_interfono_con_pantalla_lshf.html (2015-09-25)
    Open archived version from archive


  • Cervi S.A. | EAP outdoor telephone cable
    dB km 1 64 1 30 1 04 0 74 3 kHz dB km 3 18 2 52 2 01 1 42 150 kHz dB km 11 4 8 3 6 2 4 4 1000 kHz dB km 27 1 21 4 17 5 12 8 Far end crosstalk ELFEXT Cond diameter mm 0 40 0 51 0 64 0 91 1000 kHz dB 305m Minimum average 44 5 46 2 46 5 48 2 1000 kHz dB 305m Minimum 40 4 40 4 40 4 42 4 Near end crosstalk NEXT dB 305m at 1000 kH Minimum average 45 2 40 1 minimum Used as distribution cables for subscribers or linking cables between stations Installation can be in piping or suspended Flame retardant UNE EN 50265 2 1 IEC 60332 1 Colour code Pair number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Piloto Conductor 1 White White White White White Red Red Red Red Red Black Black Black Black Black Yellow Yellow Yellow Yellow Yellow Violet Violet Violet Violet Violet White Conductor 1 Blue Orange Green Brown Grey Blue Orange Green Brown Grey Blue Orange Green Brown Grey Blue Orange Green Brown Grey Blue Orange Green Brown Grey Black Bindings Unit num 1 2 3 4 5 Binding color U 25 White White White White White Construction data EAP outdoor telephone cable Code 21876500 21876600 21876700 21876800 21876900 21877000 21877100 21877200 21877300 21877400 21877500 21877600 20765200 20768000 20767600 20767700 20768100 20767000 20767900 20774000 20768400 20768200 20790600 20665200 20665300 20665400 20663400 20663500 20665000 20663600 20679700 20690800 20690900 20691000 20691100 21075800 21075900 21076400 21076300 21074900 21074800 21074700 21074200 21091200 NxS mm 6x2x0 4 11x2x0 4 16x2x0 4 26x2x0 4 51x2x0 4 76x2x0 4

    Original URL path: http://www.cervi.es/english/products/ficha_telefonico_exterior_eap.html (2015-09-25)
    Open archived version from archive